You've built a creepy haunted house and it's the scariest one around. How do you take it to the next level? Automate it using non-contact infrared photoelectric sensors to control electronic scare devices.
Haunted houses are designed to be very creepy and with enough volunteers, they may be loaded with frights around every corner. What if there are not enough volunteers available to haunt the house? Infrared photoelectric sensors are the perfect device to detect guests and to trigger electronic gadgets, such as noise makers or motorized animatronic characters, giving visitors a scare they won't soon forget.
Sensors are used every day in various industries ranging from food processing to automotive assembly lines. Some of the top commercial haunted houses in the country are now using the very same sensors to automate their haunted attractions, providing a far creepier presentation. Industrial sensors are available to the general public for less money than you might expect, giving the average Joe an opportunity to built a haunted house that rivals even the ones presented by major theme parks.
The easiest type of photoelectric sensor to use in a haunted house attraction is one that uses a mechanical relay switch. This type of sensor is as easy to wire and operate as a light switch. Also be sure that the photoelectric sensors use infrared light and do not display a visible light which would draw attention to them. Arrange the photoelectric sensors across from each other in a hallway or door jamb, or anywhere that a guest will pass between them. The guest will break the infrared beam of light, causing the mechanical relay switch in the photoelectric controller to close, which will provide power to a noise maker or animatronic device. Each time a guest passes the sensors, the same action will occur repeatedly without operator intervention. This allows volunteers in the haunted house to spend time mingling with the guests and not hiding behind walls, just making noise.
Related articles
How to Host a Spooky Halloween Karaoke Party
How to Make Trick-or-Treaters Feel Welcome
A blog with information on almost any topic imaginable . The product of years of trial and error learning.
Showing posts with label sensor. Show all posts
Showing posts with label sensor. Show all posts
Friday
Wednesday
How to Detect Boats in a Log Flume Ride
It’s time for yearly maintenance and you need a reliable solution to replace the sensors in your log flume attraction. Try industrial infrared photoelectric sensors to keep your log flume running trouble-free year round.
Purchase an industrial infrared photoelectric system. Check the ratings on the photo eyes and be sure they have an IP67 rating or better. Also check their range to be sure it is more than adequate to cover the entire distance across the river. If the photo eyes need to operate underwater, choose the most powerful combination of transmitter and receiver available.
Mount the photo eyes in a through-beam configuration for the best performance. Do not rely on reflectors because they will cause problems as they get dirty. If the photo eyes will spend any length of time underwater, it is a good idea to purchase the hard-wired cable version instead of a quick-disconnect type. If you do use quick-disconnect sensors, be sure to squirt dielectric grease into the connectors before attaching them together. This will help keep the connections dry and the pins free from corrosion.
Ask the manufacturer or distributor of photoelectric sensors for a demo set to test in your ride application before you buy. Try several sets from different companies side-by-side to determine which ones work the best. Follow a strict maintenance schedule and replace the photo eyes at least once a year. Your visitors will appreciate the extended ride uptime that quality sensors provide.
Related articles
How to Troubleshoot Photoelectric Sensors
How to Equip Amusement Rides with the Right Sensors
Purchase an industrial infrared photoelectric system. Check the ratings on the photo eyes and be sure they have an IP67 rating or better. Also check their range to be sure it is more than adequate to cover the entire distance across the river. If the photo eyes need to operate underwater, choose the most powerful combination of transmitter and receiver available.
Mount the photo eyes in a through-beam configuration for the best performance. Do not rely on reflectors because they will cause problems as they get dirty. If the photo eyes will spend any length of time underwater, it is a good idea to purchase the hard-wired cable version instead of a quick-disconnect type. If you do use quick-disconnect sensors, be sure to squirt dielectric grease into the connectors before attaching them together. This will help keep the connections dry and the pins free from corrosion.
Ask the manufacturer or distributor of photoelectric sensors for a demo set to test in your ride application before you buy. Try several sets from different companies side-by-side to determine which ones work the best. Follow a strict maintenance schedule and replace the photo eyes at least once a year. Your visitors will appreciate the extended ride uptime that quality sensors provide.
Related articles
How to Troubleshoot Photoelectric Sensors
How to Equip Amusement Rides with the Right Sensors
How to Connect a Three-wire DC Sensor to a PLC
An application calls for a three-wire DC sensor to report to a PLC. How should they be connected together? Check the input card of the PLC and find the voltage rating. Does it operate on DC voltage? Also determine whether the input needs to be sinking (NPN) or sourcing (PNP.) Look at the sensor and make sure the voltage rating and PNP / NPN type is the same. If there is a mismatch, refer to the manufacturer's instructions for both devices to determine compatibility.
If the PLC's input card is rated for DC voltage and it is a sinking (NPN) type input and also if the sensor operates on DC voltage in the same range and its output is sinking (NPN), then the two should be compatible. Connect the PLC to the power supply, but do not turn the power supply ON yet. Then connect the sensor's positive source voltage wire, which is normally brown, to the positive terminal of the power supply. Connect the negative or neutral sensor wire, normally blue, to the power supply as well, but on the negative terminal. Then connect the sensor's signal wire, normally black, to the PLC input card at the number address that you will assign as the sensor in the PLC program. When the sensor is activated, it will connect the PLC output to neutral or ground, which the PLC will interpret as a "true" condition and respond as programmed.
If the PLC's input card is rated for DC voltage and it is a sourcing (PNP) type input and also if the sensor operates on DC voltage in the same range and its output is sourcing (PNP), then the two should be compatible. Connect the PLC to the power supply, but do not turn the power supply ON yet. Then connect the sensor's positive source voltage wire, which is normally brown to the positive terminal of the power supply. Connect the negative or neutral sensor wire, normally blue, to the power supply as well, but on the negative terminal. Then connect the sensor's signal wire, normally black, to the PLC input card at the number address that you will assign as the sensor in the PLC program. When the sensor is activated, it will connect the PLC output to the positive terminal of the power supply, which the PLC will interpret as a "true" condition and respond as programmed.
Related articles
How to Test Whether a Sensor has a PNP or NPN Type Output Using a Multi meter
How to Troubleshoot Photoelectric Sensors
If the PLC's input card is rated for DC voltage and it is a sinking (NPN) type input and also if the sensor operates on DC voltage in the same range and its output is sinking (NPN), then the two should be compatible. Connect the PLC to the power supply, but do not turn the power supply ON yet. Then connect the sensor's positive source voltage wire, which is normally brown, to the positive terminal of the power supply. Connect the negative or neutral sensor wire, normally blue, to the power supply as well, but on the negative terminal. Then connect the sensor's signal wire, normally black, to the PLC input card at the number address that you will assign as the sensor in the PLC program. When the sensor is activated, it will connect the PLC output to neutral or ground, which the PLC will interpret as a "true" condition and respond as programmed.
If the PLC's input card is rated for DC voltage and it is a sourcing (PNP) type input and also if the sensor operates on DC voltage in the same range and its output is sourcing (PNP), then the two should be compatible. Connect the PLC to the power supply, but do not turn the power supply ON yet. Then connect the sensor's positive source voltage wire, which is normally brown to the positive terminal of the power supply. Connect the negative or neutral sensor wire, normally blue, to the power supply as well, but on the negative terminal. Then connect the sensor's signal wire, normally black, to the PLC input card at the number address that you will assign as the sensor in the PLC program. When the sensor is activated, it will connect the PLC output to the positive terminal of the power supply, which the PLC will interpret as a "true" condition and respond as programmed.
Related articles
How to Test Whether a Sensor has a PNP or NPN Type Output Using a Multi meter
How to Troubleshoot Photoelectric Sensors
Labels:
connect,
controller,
dc,
interface,
logic,
plc,
programmable,
sensor,
three,
wire
How to Use Sensors to Detect Missing Content from Foil Wrappers
An application to detect if the contents of a foil wrapper are missing is fairly easy to solve using two sets of industrial grade high-powered infrared photoelectric sensors.
Many industries use foil wrappers to package products. For quality control, it is a good idea to have a system capable of automatically detecting when the contents of those wrappers are missing. Some companies use human beings to manually pick and choose wrappers, which is tedious, and not very efficient. There is a solution that really works; infrared photoelectric sensors.
Position one set of infrared photoelectric sensors in a through-beam configuration, so that the foil wrapper will move between the sensors at a given point. Adjust the sensitivity of the infrared photoelectric sensors so that they will detect the foil wrapper whether it is full or empty. The sensors should be at their most sensitive setting for this. The output from this set of sensors will report to the PLC to let it know when a foil wrapper is present.
Position the second set of infrared photoelectric sensors beside the first set, also in a through-beam configuration and facing the same direction. Be sure that the sensors are set to different frequencies to avoid cross-talk between the two sets. This set of sensors should be adjusted to its least sensitive setting. In other words, crank the gain setting to the max. Assuming that the photoelectric sensors being used are industrial grade, they should be able to see through an empty wrapper easily, but not one containing product. This set should also report to the PLC.
Now, you have two infrared beams of light striking the foil wrapper as it passed. One is used as a reference to let the PLC know when a foil wrapper is present. The second set of sensors lets the PLC know when a foil wrapper is missing its expected contents. This system is very reliable and is in use at a number of companies worldwide.
Related articles
How to Troubleshoot Photoelectric Sensors
How to Connect a Three-wire DC Sensor to a PLC
Many industries use foil wrappers to package products. For quality control, it is a good idea to have a system capable of automatically detecting when the contents of those wrappers are missing. Some companies use human beings to manually pick and choose wrappers, which is tedious, and not very efficient. There is a solution that really works; infrared photoelectric sensors.
Position one set of infrared photoelectric sensors in a through-beam configuration, so that the foil wrapper will move between the sensors at a given point. Adjust the sensitivity of the infrared photoelectric sensors so that they will detect the foil wrapper whether it is full or empty. The sensors should be at their most sensitive setting for this. The output from this set of sensors will report to the PLC to let it know when a foil wrapper is present.
Position the second set of infrared photoelectric sensors beside the first set, also in a through-beam configuration and facing the same direction. Be sure that the sensors are set to different frequencies to avoid cross-talk between the two sets. This set of sensors should be adjusted to its least sensitive setting. In other words, crank the gain setting to the max. Assuming that the photoelectric sensors being used are industrial grade, they should be able to see through an empty wrapper easily, but not one containing product. This set should also report to the PLC.
Now, you have two infrared beams of light striking the foil wrapper as it passed. One is used as a reference to let the PLC know when a foil wrapper is present. The second set of sensors lets the PLC know when a foil wrapper is missing its expected contents. This system is very reliable and is in use at a number of companies worldwide.
Related articles
How to Troubleshoot Photoelectric Sensors
How to Connect a Three-wire DC Sensor to a PLC
Thursday
How to Measure Level of Material in a Large Bin or Hopper
Let's say you have a large bin or hopper and you regularly fill it with wood chips or powder or even liquid. How can you accurately measure the level in the bin? In applications where it is necessary to measure the level of material in a large collection bin, there is not always an obvious way. This article will describe one method, using an ultrasonic sensor.
Purchase an industrial ultrasonic sensor (uses sound waves) with a range long enough to bounce from the top of the bin down to the lowest possible level of the material, or at least the lowest level that you care to measure. Be sure to select an ultrasonic sensor with an analog output. Be aware that all ultrasonic sensors have a "blind zone" beginning at the face of the sensor and extending to various distances away. For this reason, the material to be measured should never be allowed to enter this "blind zone" because accurate measurement cannot take place in this range. Also note that ultrasonic sensors are affected by drastic changes in temperature and may need to be recalibrated occasionally.
Install the ultrasonic sensor in the top of the bin pointing downward so that it faces the material in the bin. The analog output from the sensor will need to interface with the PLC or computer so that the reading may be interpreted and any necessary functions may take place when the level reaches certain points.
Empty the bin and take note of the output from the sensor. Then, fill the bin to the maximum desired level and take another reading from the sensor. Now you have your high and low margins. You can program certain things to happen when the material hits a certain level, for instance, when the level of water in a bin reaches the top, the pump that supplies the water shuts off until the water is lowered again to another predetermined level.
Related articles
How to Test Whether a Sensor has a PNP or NPN Type Output Using a Multi meter
How to Connect a Three-wire DC Sensor to a PLC
Purchase an industrial ultrasonic sensor (uses sound waves) with a range long enough to bounce from the top of the bin down to the lowest possible level of the material, or at least the lowest level that you care to measure. Be sure to select an ultrasonic sensor with an analog output. Be aware that all ultrasonic sensors have a "blind zone" beginning at the face of the sensor and extending to various distances away. For this reason, the material to be measured should never be allowed to enter this "blind zone" because accurate measurement cannot take place in this range. Also note that ultrasonic sensors are affected by drastic changes in temperature and may need to be recalibrated occasionally.
Install the ultrasonic sensor in the top of the bin pointing downward so that it faces the material in the bin. The analog output from the sensor will need to interface with the PLC or computer so that the reading may be interpreted and any necessary functions may take place when the level reaches certain points.
Empty the bin and take note of the output from the sensor. Then, fill the bin to the maximum desired level and take another reading from the sensor. Now you have your high and low margins. You can program certain things to happen when the material hits a certain level, for instance, when the level of water in a bin reaches the top, the pump that supplies the water shuts off until the water is lowered again to another predetermined level.
Related articles
How to Test Whether a Sensor has a PNP or NPN Type Output Using a Multi meter
How to Connect a Three-wire DC Sensor to a PLC
Subscribe to: