Showing posts with label close. Show all posts
Showing posts with label close. Show all posts

Saturday

How to Equip Amusement Rides with the Right Sensors

The best types of sensors in an amusement park are the ones you don’t think about until maintenance time. Find the most reliable products and they will save you money and headaches all year long.

Evaluate each amusement ride individually. What type of sensing solution is currently in place? How well does it work? If it is possible to replace contact switches, otherwise known as limit switches, with a non-contact solution, it will greatly improve the uptime for that ride. Contact switches with moving parts wear out quickly, whereas non-contact sensors only need to be replaced in the event that they are destroyed by collision, Mother Nature, or extremely rough handling. Consult with a manufacturer or distributor of industrial sensors and ask them for assistance with your application. Any sensor company who is interested in doing business with you should be able to support the products and answer your questions.

If a new sensor is what you desire, the next decision is which type of sensing technology to implement. There are many sensors to choose from, but in the amusement industry, the top picks are infrared photoelectric sensors and inductive proximity sensors. A transmitter photo eye projects an infrared beam of light, which is invisible to the naked human eye. A receiver photo eye reports when it sees the beam and when it doesn’t and will pass a signal to the appropriate controller. Rides that require objects to be detected from a distance or in harsh conditions, like log flume rides, river rapids, and dark, smoky theme rides are great places for photoelectric sensors.

Try an inductive proximity sensor in areas where metal objects must be detected at close range. These sensors will only detect metal and their sensing distance is limited, but they are extremely tough and can take a beating. Rides like roller coasters, where the sensor may be mounted on the track and detect the metal in the train are good applications for inductive proximity sensors. Inductive proximity sensors are excellent replacements for limit switches.

Develop a routine maintenance schedule and replace all sensors in the amusement park at least once a year. This will ensure proper function and will keep the rides operating at their peak performance. Visitors will appreciate the ride availability and you will notice improved uptime and fewer replacements throughout the year.

Supplier of Industrial Photoelectric Sensors

Related articles
How to Detect Boats in a Log Flume Ride
How to Troubleshoot Photoelectric Sensors

Wednesday

How to Operate an Automatic Door Using Infrared Photoelectric Sensors

An automatic door is not complete without infrared photoelectric sensors to control it. Photo eyes provide a non-contact method to detect people or objects passing through the door and may be used in conjunction with a controller to open the door.

Choose a quality set of industrial infrared photoelectric sensors. It is imperative that sensors are used on an automatic door, not just to open the door, but to prevent the door from closing with a person or object underneath. Photoelectric sensors are ideal for this application because they do not require the door to make contact with the subject to detect their presence. Ultimately, the manufacturer should provide wiring diagrams and installation instructions to help interface sensors or other input devices with the door controller, but the following instructions should give you a general idea of how they should be used.

Mount the photoelectric sensors in a through-beam configuration. This will save you a lot of trouble later. Do not try to mount the photo eyes on one side and use a reflector on the other because you will find yourself constantly cleaning the reflector. Infrared photoelectric sensors provide a stronger and much more reliable beam when they are mounted across from each other. If the photoelectric system that you are using includes an external amplifier, compare the voltage ratings for the photoelectric system and the PLC. If they are a match, connect the output from the amplifier to the door's PLC input card.

Configure the photoelectric system to output all the time, but then take away that output when the photo eyes detect something. This is commonly listed by the manufacturer as a feature known as "Normally Closed", "Light Operate", or "Make Switching." Program the PLC to interpret an output from the photoelectric system as a "false" condition and the absence of that output as a "true" condition. When the PLC reads a "true" condition, it should open the door, and when the condition returns to "false" it should close the door. This does two things, it opens the door when an object is detected and also if the photoelectric system experiences a fault or loss of power.


Related articles
How to Test Whether a Sensor has a PNP or NPN Type Output Using a Multi meter
How to Troubleshoot Photoelectric Sensors